Defibrillator Analyzer / Pacemaker Tester
An Ultimate Defibrillator Analyzer and Pacer Tester with built in ECG Simulator for testing all Defibrillators and Pacemakers.
DELTA 3000 - A three in one unit with Defibrillator Analyzer / Pacemaker Analyzer and ECG Simulator.
DELTA 3000, Defibrillator Analyzer / Pacemaker Tester is the latest addition of our Defibrillator Analyzer with full Pacer Tester and ECG Simulator built in.
DELTA 3000, Defibrillator Analyzer / Pacemaker Tester combines the complete testing functions of a Defibrillator Tester, a Pacemaker Analyzer, and a 12 Lead ECG / Arrhythmia simulator into one compact, lightweight, and easy to use instrument. No other instrument delivers the performance testing power of the
DELTA 3000 Defibrillator Analyzer / Pacemaker Tester.
DELTA 3000, Defibrillator Analyzer / Pacemaker Tester tests all defibrillators including AEDs. It measures both monophasic and bi-phasic waveforms. It tests all external pacemakers including Transthoracic, Transvenous, and AV sequential models. It has 12 built-in user selectable test loads for Transthoracic pacing testing. The built-in ECG / Arrhythmia simulator allows performance testing of any ECG equipment.
|
 |
 |
 |
Compact, Lightweight, and Rugged |
 |
Simple, Menu Driven Operation |
 |
Large 4-line LCD |
 |
Simultaneous Display of All Test Measurements |
 |
Dedicated Print Key for Immediate Documentaion |
 |
RS 232 Interface |
 |
Battery or AC Operation |
 |
Two-Year Warranty
|
| |
|
| |
|
| |
|
 |
 |
Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time |
 |
Storage and Playback of output waveforms |
 |
Tests all External Pacemakers - Transthorasic, Transvenous, and AV Pacers |
 |
Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refactory Periods |
 |
50 and 60 Hz Immunity Tests |
 |
Transthorasic Test Loads: Fixed 50 Ohm or 12 User Selectable Loads to 1000 Ohmst |
 |
A / V Pacer Test Load: 500 Ohm |
 |
ECG Simulator: |
| |
|
| |
- 12 lead ECG, User Selectabel Rates and Amplitudes
|
| |
- Performance Waveforms: Sine, Square, Triangle, and Pulse
|
| |
|

|
|
Defibrillator Analyzer
0-1999
nergy Measurement: Load: 50 Ohm ± 1 %
Range (High): 900 J, Res.1 J
Resolution: 1 Joules
Range (Low): 0 - 100
Resolution: 0.1 Joules
Accuracy: ± 2% of the reading
+ 1 J for Hi Range or
+ 0.5 J for Low Range
Maximum Voltage: 5200 V
Maximum Current: 100 Amp (H)
Sync. Time: 0 - 250 ms
Waveform Output:
Real Time: Output 1000 : 1 Stored.
Discharge waveform expanded 200:1 and is repeated 8 sec. It can be viewed through the paddles and through the ECG High Level Output
Pacemaker Analyzer
Transcutaneous:
Test Load: 50 Ohm (Fixed) and variable 100 to 1000 Ohms user selectable
Current: 1 to 200 mA
Accuracy: ± 5% + 0.5 mA
Pulse Width: 0.5 to 80 ms
Accuracy: ± 1% + 0.1 ms
Refractory: 20 - 500 ms
Accuracy: ± 2% or + 10 ms
Atrial and Ventricular:
Test Load: 500 Ohms
Current: 1 to 25 mA
Accuracy: ± 5% + 0.5 mA
Pulse Rate: 30 to 800 ppm.
Accuracy: ± 1% + 0.1 ms
Refactory: ± 20 - 500 ms
Accuracy: ± 2% or 10 ms
Immunity Test: 50 / 60 Hz
ECG ArrhythmiaSimulator
ECG: Normal Sinus Rhythm.
Rate: 30, 60, 90, 120, 240
Performance: Sine, Square, Triangle and Pulse
Rate: 0.5, 1, 2, 10, 15, 20, 25, 40 Hz
Arrhythmias:
VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR
Waveform Output: 12 Lead ECG and Paddle and High Level Output Jacks.
|
Power Requirements: |
: |
Two 9V Alkaline Batteries Or AC Adapter |
Dimension: |
: |
10 x 11 x 2.25 inches
(25.4 x 27.9 x 5.7 cm)
|
Weight: |
: |
4 lbs (1.8 kg) |
|
|
 |
| Part Number |
Description |
Price |
650-A |
Basic Defibrillator Analyzer with Pacer (Include carrying case, AC Adapter, Universal Adapter) |
|
650 |
Full Function Defibrillator Analyzer with Pacer Including A/V (Includes Carrying case, Ac Adapter, Standard Interface Cables adaptable to any Pacers / Defibrillators) |
|
650-Case |
Carrying case (Hard Case) |

|
650-302 |
AC Adapter |

|
For various Interface cables (Model Specific) |
For Manufacturer Specific Interface Cables Call 1-800-547-6557 for Part Number and Price |
|
|
|
 |
|








|